Active Network Access Control System provide the solution for powerful combinations of door access control and alarm monitoring within off-line networks.

The System is now capable to handle

  • 1 doors / 2 readers with a single controller.
  • 2 doors / 4 readers with a single controller.
  • 4 doors / 4 readers with a single controller.

Can fits to any type of installations, up to 20,000 users, from single buildings to multiple sites spread over remote locations and linked via RS485, RS232 or TCP/IP.

The user-friendly Access software programs the system within a few minutes, from a non-dedicated PC. Access Software provides numerous access control and alarm monitoring features: expiry date for clubs, automatic activation, interlock between two doors, time zones, supervision, anti-passback, activity reports…

Each alarm input is programmable: operating mode (NO or NC), time zones, local reflex (activation of outputs according to input status). Specific alarms are triggered according to the number of unsuccessful attempts, the time limit for door closing (door alarm), the duress code…

Whenever required, the data stored in the controllers is transferred to the computer and activity reports are printed. Each controller works independently and keeps its own database.

The Advantage of New WEB-Based Enable Multi Door Access Control Board

  • No Software to install
  • Simply connect a TCP/IP network cable from VAB-W Series control board to computer and use web browser for access control
  • Easy to use and operate, enroll, remote control and configuration via the web browser.
  • Low cost design and no need special IT infrastructures

WEB-Based Enable Multi Door Access Control Board

VAB-W10

Single Door Access Controller

  • Communication – TCP/IP, Web-Based Enable;
  • Single door, two readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 1 door, 1 pc relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

VAB-W20

Two Door Access Controller

  • Communication – TCP/IP, Web-Based Enable;
  • Two doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 2 doors, 2 pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

VAB-W40

Four Door Access Controller

  • Communication – TCP/IP, Web-Based Enable;
  • Four doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 4 doors, 4pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

Support TCP/IP Communication

VAB-T10

Single Door Access Controller

  • Communication – TCP/IP;
  • Single door, two readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 1 door, 1 pc relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

VAB-T20

Two Door Access Controller

  • Communication – TCP/IP;
  • Two doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 2 doors, 2 pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

VAB-T40

Four Door Access Controller

  • Communication – TCP/IP;
  • Four doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 4 doors, 4pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

Support RS485 Communication

VAB-R10

Single Access Door Controller

  • Communication – RS485;
  • Single door, two readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 1 door, 1 pc relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

VAB-R20

Two Access Door Controller

  • Communication – RS485;
  • Two doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 2 doors, 2 pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA

 

VAB-R40

Four Access Door Controller

  • Communication – RS485;
  • Four doors, four readers;
  • Capacity: 20,000 users / 100,000 event buffers;
  • Door control: 4 doors, 4pcs relay;
  • Baud Rate: 9600 bps;
  • Operating Temperature: -40C0 – 70 C0;
  • Power Supply Input: 12 Vdc
  • Operational humidity: 0 to 95% RH;
  • Working voltage: 9.5 V to 14 VDC;
  • Current consumption: max. 100 mA